María-José Paredes-Ruiz1, Maria Jodar-Reverte1, Vicente Ferrer-Lopez1, Ignacio Martínez- González-Moro1

1University of Murcia, University Institute for Researching in Aging, Research Group: Physical Exercise and Human Performance, Murcia, Spain

Quadriceps Muscle Oxygenation during a Maximum Stress Test in Middle-Aged Athletes

Monten. J. Sports Sci. Med. 2020, 9(2), 43-49 | DOI: 10.26773/mjssm.200908

Abstract

Determining oxygen muscle saturation (SmO2) using near-infrared spectroscopy (NIRS) is an emerging technique that is increasingly used in sports science; therefore, it is necessary to know its results in different population groups. We analysed it in a group of recreational participants in Nordic Walking. The purpose of this research was to analyse the SmO2 values obtained at various times from testing in a group of athletes over 45. Thirty athletes (18 males) with a mean age of 51.3 years completed a maximal exercise testing in treadmill according to a modified Bruce protocol on a ramp. The electrocardiogram was continuously monitored. We measured VO2max (Metalyzer 3B). In addition, we placed a Humon Hex device on the right thigh to measure quadriceps oxygenation. Heart rate, VO2, and SmO2 ratios were obtained based on the exercise intensity. We obtained a SmO2 at startup of 63.3%, standard deviation (SD) 9.2%; SmO2 declined 61.8%, SD 11.4%; SmO2 in VO2max 57.4% SD 10.2% and SmO2 5 minutes after starting recovery 72.5% SD7.9%. There was a relationship between ventilatory thresholds and variations in SmO2. There were no significant differences between the sexes. We could conclude that the minimum values of SmO2 were related to the VO2 max. During the recovery phase, the values were higher than at rest. The information obtained could be used to control and plan the training.

Keywords

nordic walking, muscle oxygenation, maximal exercise testing



View full article
(PDF – 405KB)

References

Chang, S. C., Adami, A., Lin HC, Lin, Y. C., Chen, C. P., Fu, T. C., … Huang, S. C. (2019). Relationship between maximal incremental and high-intensity interval exercise performance in elite athletes. bioRxiv, 856237. Retrieved 11/30, 2019, from https://www.biorxiv.org/content/10.1101/856237v1

Contreras-Briceño, F., Espinosa-Ramirez, M., Hevia, G., Llambias, D., Carrasco M., Cerda, F., … Viscor, G. (2019). Reliability of NIRS portable device for measuring intercostal muscles oxygenation during exercise. Journal of Sports Sciences, 37(23), 2653-2659. https://doi.org/10.1080/02640414.2019.1653422

Crum, E. M., O’Connor, W. J., Van Loo, L., Valckx, M. & Stannard, S. R. (2017). Validity and reliability of the Moxy oxygen monitor during incremental cycling exercise. European Journal of Sport Science, 17(8), 1037-1043. https://doi.org/10.1080/17461391.2017.1330899

Doering, T. M., Coxa, G. R., Aretac, J. L., & Coffeya,V. G. (2019). Repeated muscle glycogen supercompensation with four days recovery between exhaustive exercise. Journal of Science and Medicine in Sport, 22, 907–911. https://doi.org/10.1016/j.jsams.2019.03.009

Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018). Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle. Physiological Reports, 6(7), e13664. https://doi.org/10.14814/phy2.13664

Ferrari, M., Muthalib, M., & Quaresima, V. (2011). The use of near-infrared spectroscopy in understanding skeletal muscle physiology: recent developments. Philosophical Transactions of Royal Society A, 369: 4577-4590. https://doi.org/10.1098/rsta.2011.0230

Fletcher, J. R., Esau, S. P., & MacIntosh, B. R. (2009) . Economy of running: beyond the measurement of oxygen uptake. Journal Applied Physiology, 107, 1918-1922. https://doi.org/10.1152/japplphysiol.00307.2009

Gepner, Y., Wells, A. J., Gordon, J. A., Arroyo, E., Varanoske, A. N., Coker, N. A. … Hoffmann, J.R., (2019). Differences in muscle oxygenation between young and middle-aged recreationally active men during high-volume resistance exercise. Kinesiology. 51(1), 3-11. https://doi.org/10.26582/k.51.1.4

Grassi, B., & Quaresima, V. (2016). Near-infrared spectroscopy and skeletal muscle oxidative function in vivo in health and disease: a review from an exercise physiology perspective. Journal of Biomedical Optics, 21(9): 091313. https://doi.org/10.1117/1.JBO.21.9.091313.

Hamaoka, T,. & McCully, K. K. (2019). Review of early development of near infrared spectroscopy and recent advancement of studies on muscle oxygenation and oxidative metabolism. The Journal of Physiological Sciences, 69(1), 799–811. https://doi.org/10.1007/s12576-019-00697-2

Hawkins, M. N., Raven, P. B., Snell, P. G., Stray-Gundersen, J., & Levine, B. D. (2007). Maximal Oxygen Uptake as a Parametric Measure of Cardiorespiratory Capacity. Medicine & Science in Sports & Exercise, 39(1), 103-107. https://doi.org/10.1249/01.mss.0000241641.75101.64

Hearris, M. A., Hammond, K. M., Fell, J. M., & Morton, J. P. (2018). Regulation of muscle glycogen metabolism during exercise: inplications for endurance performance and training adaptations. Nutrients, 10, 298. https://doi.org/10.3390/nu10030298

Howley, E. T., Bassett, D. R., & Welch, H. G. (1995). Criteria for maximal oxygen uptake: review and commentary. Medicine and Science in Sports and Exercise, 27(1), 1292-1292.

Humon io (2020). The Humon training zones. Retrieved 02/03, 2020, from https://humon.io/use-case/

Inglis, E.C., Iannetta, D., & Murias, J. M. (2017). The plateau in the NIRS derived (HHb) signal near the end of a ramp incremental test does not indicate the upper limit of O2 extraction in the vastus lateralis. American Journal of Physiology Regulatory Integrative and Comparative Physiology, 313, R723–R729. https://doi.org/10.1152/ajpregu.00261.2017

Karatzanos, E., Paradisis, G., Zacharogiannis, E., Tziortzis, S.,& Nanas, S. (2010). Assessment of ventilatory threshold using near-infrared spectroscopy on the gastrocnemius muscle during treadmill running. International Journal of Industrial Ergonomics, 40, 206–211. https://doi.org/10.1016/j.ergon.2009.02.003

Lam, Y. Y., & Ravussin, E., (2016). Analysis of energy metabolism in humans: A review of methodologies. Molecular Metabolism, 5(11), 1057-1071. https://doi.org/10.1016/j.molmet.2016.09.005

Mocera, F., Aquilino, G., & Somà, A. (2018). Nordic walking performance analysis with an integrated monitoring system. Sensors, 18(5), 1505. https://doi.org/10.3390/s18051505

Murphy, M. H., Lahart, I., Carlin, A., & Murtagh, E. (2019). The Effects of Continuous Compared to Accumulated Exercise on Health: A Meta Analytic Review. Sports Medicine. 49(1), 1585-1607. https://doi.org/10.1007/s40279-019-01145-2

Padulo, J., Iuliano, E., Dello Iacono, A., Milic, M., Rizzi, M., & Ardigò, L. P. (2018). Nordic walking versus natural walking: an easy approach to comparing metabolic demands. International Journal of Performance Analysis in Sport, 18(5), 686-692. https://doi.org/10.1080/24748668.2018.1514565

Pellegrin, B., Boccia, G., Zoppirolli, C., Rosa, R., Stella, F., Bortolan, L., … Schena, F. (2018). Muscular and metabolic responses to different Nordic walking techniques, when style matters. PLoS ONE 13(4): e0195438. https://doi.org/10.1371/journal.pone.019543

Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman C. A., & Drummond, C. K. (2019). Wearable sensors for monitoring the internal and external workload of the athlete. NPJ Digital Medicine, 2(71). doi :10.1038/s41746-019-0149-2

Slaght, J., Sénéchal, M., Hrubeniuk, T. J., Mayo, A., & Bouchard, D. R. (2017). Walking cadence to exercise at moderate intensity for adults: a systematic review. Journal of Sports Medicine, 4641203. https://doi.org/10.1155/2017/4641203.

Takaishi,T., Sugiura, T., Katayama, K., Sato, Y., Shima, N., Yamamoto, T., & Moritani, T. (2002). Changes in blood volume and oxygenation level in a working muscle during a crank cycle. Medicine & Science in Sports & Exercise, 34(3), 520-528. https://doi.org/10.1097/00005768-200203000-00020

Takeshima, N., Islam, M. M., Rogers, M. E., Rogers, N. L., Sengoku, N., Koizumi, D., ... Naruse, A. (2013). Effects of nordic walking compared to conventional walking and band-based resistance exercise on fitness in older adults. Journal of Sports Science and Medicine, 12, 422-430.

Tschentscher, M., Niederseer, D., & Niebauer, J. (2013). Health benefits of Nordic walking: a systematic review. American Journal of Preventive Medicine. 44(1), 76-84. https://doi.org/10.1016/j.amepre.2012.09.043

van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A.R., … DE Ruiter, C.J. (2016). Oxygenation threshold derived from near-infrared spectroscopy: reliability and its relationship with the first ventilatory threshold. PLoS ONE, 11(9), e0162914. https://doi.org/10.1371/journal.pone.0162914

Wewege, M. A., Thom, J. M., Rye, K. A., & Parmenter, B. J. (2018). Aerobic, resistance or combined training: A systematic review and meta-analysis of exercise to reduce cardiovascular risk in adults with metabolic syndrome. Atherosclerosis, 274 (1), 162-171. https://doi.org/10.1016/j.atherosclerosis.2018.05.002

Wilkinson, T. J, White, A. E. M., Nixon, D, G, D., Gould, D. W., Watson, E., L. & Smith, A. C. (2019). Characterising skeletal muscle hemoglobin saturation during exercise using near-infrared spectroscopy in chronic kidney disease. Clinical and Experimental Nephrology 23, 32-42. https://doi.org/10.1007/s10157-018-1612-0

Yamamoto, J., Harada T., & Okada, A. (2014). Difference in Physiological Components of VO2 Max during Incremental and Constant Exercise Protocols for the Cardiopulmonary Exercise Test. Journal of Physical Therapy Science, 26, 1283–1286. https://doi.org/10.1589/jpts.26.1283